Photovoltaic

Photovoltaic

Market prospects and trends: The photovoltaic industry is a new energy industry that encourages the development of the world, and it is also an integral part of the strategic emerging industries supported by various countries.In the context of climate change, energy crises, and repeated epidemics, countries around the world attach great importance to sustainable development and vigorously support the transformation of green and low-carbon energy. Driven by technological breakthroughs in renewable energy and policy tools, the scale of the global photovoltaic market has maintained a good development trend.


Standard introduction:

  • NB/T 32004 PHOTOVOLTAIC grid-connected inverter technical specifications


Application Diagram

光伏1光伏2

Product List

Series Model Package style Certification/Standard Rated current
[mA]
Maximum current
[mA]
Overcurrent capability
(A)
Operating temperature accuracy%
(25℃)
Applicable power segment
SM Series RCMU101SM1-2AI RCMU101SM1-2AI CE/UL 300mA 500mA 20A -40℃~105℃ 2 0-4kW
RCMU101SM2-AI RCMU101SM2-AI CE/UL 300mA 500mA Customize -40℃~105℃ 2 0-4kW
RCMU101SM3-6AI RCMU101SM3-6AI CE/UL 300mA 500mA 42A -40℃~105℃ 2 0-10kW
RCMU101SM3-6FI RCMU101SM3-6FI CE/UL 510mA 850mA 42A -40℃~105℃ 2 0-10kW
RCMU101SM4-2AI RCMU101SM4-2AI CE/UL 300mA 500mA 20A -40℃~105℃ 2 0-4kW
Series Model Package style Certification/Standard Rated current
[mA]
Maximum current
[mA]
Overcurrent capability
(A)
Operating temperature accuracy%
(25℃)
Applicable power segment
SN Series RCMU101SN-2P12C-5NB RCMU101SN-2P12C-5NB CE/UL 1020mA 1700mA 70A -40℃~105℃ 2 0-15kW
RCMU101SN-2P2A-5N RCMU101SN-2P2A-5N CE/UL 300mA 500mA 20A -40℃~105℃ 2 0-4kW
RCMU101SN-2P12A-5N RCMU101SN-2P12A-5N CE/UL 300mA 500mA 70A -40℃~105℃ 2 0-15kW
RCMU101SN-2P4A-5S RCMU101SN-2P4A-5S CE/UL 300mA 500mA 32A -40℃~105℃ 2 0-7kW
RCMU101SN-3P6A-5S RCMU101SN-3P6A-5S CE/UL 300mA 500mA 42A -40℃~105℃ 2 0-36kW
RCMU101SN-3P6C-5S RCMU101SN-3P6C-5S CE/UL 1020mA 1700mA 42A -40℃~105℃ 2 0-36kW
RCMU101SN-3P28A-5S RCMU101SN-3P28A-5S CE/UL 300mA 500mA 120A -40℃~105℃ 2 0-150kW
RCMU101SN-3P28C-5S RCMU101SN-3P28C-5S CE/UL 1020mA 1700mA 120A -40℃~105℃ 2 0-150kW
RCMU101SN-4P4A-5S RCMU101SN-4P4A-5S CE/UL 300mA 500mA 32A -40℃~105℃ 2 0-20kW
RCMU101SN-4P4C-5S RCMU101SN-4P4C-5S CE/UL 1020mA 1700mA 32A -40℃~105℃ 2 0-20kW
RCMU101SN-4P5C-5N RCMU101SN-4P5C-5N CE/UL 1020mA 1700mA 40A -40℃~105℃ 2 0-25kW
RCMU101SN-4P10A-5S RCMU101SN-4P10A-5S CE/UL 300mA 500mA 60A -40℃~105℃ 2 0-60kW
RCMU101SN-4P16A-5S RCMU101SN-4P16A-5S CE/UL 300mA 500mA 80A -40℃~105℃ 2 0-80kW
RCMU101SN-4P16C-5S RCMU101SN-4P16C-5S CE/UL 1020mA 1700mA 80A -40℃~105℃ 2 0-80kW
RCMU101SN-A-5S RCMU101SN-A-5S CE/UL 300mA 500mA Customize -40℃~105℃ 2 /
RCMU101SN-C-5S RCMU101SN-C-5S CE/UL 1020mA 1700mA Customize -40℃~105℃ 2 /
RCMU101SN-D-5S RCMU101SN-D-5S CE/UL 1500mA 2000mA Customize -40℃~105℃ 2 /
RCMU101SN-G-6C RCMU101SN-G-6C CE/UL 3000mA 5000mA Customize -40℃~105℃ 1.5 /
RCMU101SN-3P50G-6C RCMU101SN-3P50G-6C CE/UL 3000mA 5000mA 300A -40℃~105℃ 1.5 0-300kW
Series Model Package style Rated current
[A]
Maximum range
[A]
Supply voltage
(V)
Frequency bandwidth Operating temperature
[℃]
linearity
(25℃)
accuracy%
(25℃)
Application scenario
Flux Gate Current Sensor MCSC-200S/NP MCSC-200S/NP 200A 450A +5V 200kHz -40~+85 0.1% 0.7% Photovoltaic inverter/industrial equipment
Series Model Package style Rated current
[A]
Maximum range
[A]
Supply voltage
(V)
Frequency bandwidth Operating temperature
[℃]
linearity
(25℃)
accuracy%
(25℃)
Application scenario
Hall Open Loop Current Sensor MG10RAG MG10RAG 10A 25A +5V 200kHz -40~+105 0.5% 1% Combiner box/inverter
MG16RAG MG16RAG 16A 40A +5V 200kHz -40~+105 0.5% 1% Combiner box/inverter
MG20RAG MG20RAG 20A 50A +5V 200kHz -40~+105 0.5% 1% Combiner box/inverter
MG32RAG MG32RAG 32A 80A +5V 200kHz -40~+105 0.5% 1% Combiner box/inverter
MG50RAG MG50RAG 50A 125A +5V 200kHz -40~+105 0.5% 1% Combiner box/inverter
MC20 MC20 10A 20A +5V 80kHz -40~+85 0.4% 1% Combiner box/industrial equipment
MC25 MC25 12.5A 25A +5V 80kHz -40~+85 0.4% 1% Combiner box/industrial equipment
MC45 MC45 22.5A 45A +5V 80kHz -40~+85 0.4% 1% Combiner box/industrial equipment
ME2-20 ME2-20 10A 20A +5V 80kHz -40~+85 0.4% 1% Combiner box/industrial equipment